Up to eight Gamry potentiostats in one system, where every channel is a full research-grade instrument rather than a shared module — so throughput goes up without per-channel performance coming down. Run the channels separately, in groups, or all at once.

What it does
  • Every channel has the capabilities of a single research-grade instrument — no performance traded for throughput
  • Up to eight potentiostats in one system, mixed to suit the work: eight Interface 1010s, or a Reference 3000 driving a 30K Booster
  • No chassis slots given up to EIS, low-current or high-current modules
  • Any experiment on any channel, whatever the other channels are running
  • Greatly discounted cost-per-channel against the same instruments bought separately
For applications including
// Research citations

Cited in the literature

Independent research citations for this instrument are provided by Bioz and appear here once the widget loads.

Citation data provided by Bioz.
// Overview

Gamry’s multichannel potentiostat systems combine multiple research-grade instruments into a single, flexible system. This flexibility gives you the ability to run each channel separately, in groups, or all at once. Contact us to find out what options are available.

Applications include:

  • Coatings Analysis
  • Microbial Fuel Cells
  • Large Scale Supercapacitor and Battery Evaluation
  • Continuous Corrosion Monitoring
  • Monitoring Electrode Arrays
  • Sensor Arrays
  • Combinatorial Testing

Product Details

Multichannel Potentiostat Overview

The multichannel potentiostat combines up to eight Gamry potentiostats into a single system. Our flexibility allows you to pick and choose how you want your multichannel system configured all without having to sacrifice chassis slots for EIS, low-current, or high-current modules.

Perhaps you want the value of eight Interface 1010's combined with the high performance of a Reference 3000 connected to a Reference 30K Booster. Each channel of a multichannel system has the same capabilities as a single research-grade instrument, but at a greatly discounted cost-per-channel—there is no sacrifice in performance to gain higher experimental throughput.

Note that the Accuracy Contour Plot shown here is the same for each channel in an eight-channel Interface system.

Applications

Gamry’s full line of application software is available for all multichannel systems. Using the flexibility of the Gamry software, each channel can be run both independently and simultaneously. Any experiment can be run on any channel, regardless of which experiments are running on other channels.

Multichannel systems are ideal for any application that benefits from higher throughput.

  • Coatings Analysis
  • Microbial Fuel Cells
  • Large Scale Supercapacitor and Battery Evaluation
  • Continuous Corrosion Monitoring
  • Monitoring Electrode Arrays
  • Sensor Arrays
  • Combinatorial Testing

Regardless of the application, a Gamry multichannel potentisotat system gives you the ability to independently and simultaneously control experiments across multiple electrochemical cells.

// Specifications

The complete technical detail

USB Input
SpeedUSB High Speed
Specification ComplianceUSB 2.0
Max Input Current100 mA
Instrument USB Ports
SpeedUSB High Speed
Specification ComplianceUSB 2.0
Typical Power Supply Current<10 mA
Max Power Supply Current50 mA
Expansion USB Ports
Expansion USB PortsUSB High Speed
Specification ComplianceUSB 2.0
Max Power Supply Current (both ports) (assuming 10 mA/instrument)420 mA
Environmental
Operating Temperature Range0 to 45°C
Relative Humidity90 (non-condensing)%
Storage and Shipping Temperature-40 to 75°C
Maximum Shipping acceleration30 G
General
AC Line Input Voltage90 - 264 volts
Power700 W
Dimensions30 × 40 × 65 cm
Weight8.0 kg