The Top
Five Reasons To NOT Buy Your Next Potentiostat from Gamry
|
||
|
1. The Series G Potentiostat is installed inside a
computer
First things first. If, for some reason, you just don't want to even consider installing your potentiostat in a computer, then you need the Reference 600 Potentiostat or the Reference 3000 Potentiostat, which interfaces to a computer with a USB interface. If you are considering the Series G, there are several practical reasons why installing a Potentiostat inside a computer is a good idea. There's no need for an expensive cabinet, power supply, or front panel. Result? A lower price! Don't believe it? Then contact us and request a Price List. Why must an electrochemical instrument have a rat's nest of cables connecting this box to that box? A Gamry Series G is simple -- the only cable you see is the cell cable! A Gamry Series G System uses only one box -- the computer -- so it saves bench space.
Portability is
easy. Install the Gamry Series G in an eStation
Portable Electrochemistry System and you've got
research-grade electrochemistry you can carry in one hand!
|
||
|
2. I need a very high
compliance voltage.
If you're doing electrochemical experiments in a high-resistance electrolyte in which high currents (>500 mA) are observed, you may need a higher compliance voltage than Gamry offers. When do you observe high currents in high-resistance electrolytes? In electrochemical synthesis experiments in non-aqueous solvents or very dilute aqueous electrolytes. That's about it. It's a very uncommon situation. You may have high currents in a battery or a fuel cell, but the resistance is very low. You may have corrosion taking place in a high-resistance electrolyte, but the currents are very low. In physical electrochemistry experiments, the currents are usually low and the researcher has the flexibility to adjust the resistance of the electrolyte. If your electrochemistry is done in a reasonably conductive solvent (even pure water), a potentiostat with a high compliance voltage is not better -- it's just a lot more expensive and a lot more dangerous. The number of electrochemical experiments where a high compliance voltage is justified is both very small and easily identified. Because a high compliance voltage is expensive, we don't believe it's a wise choice for the vast majority of electrochemical users.
|
||
|
3. I need to go to 1 MHz
with my EIS System.
If a 1 MHz specification is a requirement, then you need the Reference 600 Potentiostat or the Reference 3000 Potentiostat. EIS with our Series G Potentiostats has a maximum frequency of 300 kHz. For all Gamry Potentiostats, the accuracy of our EIS measurement is <1% error in impedance and <2° error in phase throughout the entire frequency range of the measuerment. |
||
|
4. My
potentiostat must communicate with oscilloscopes and function generators
and thermocouples and rotating electrodes and other things in the outside
world!
That's not a problem. On every Gamry Potentiostat, there are analog outputs for potential and current, and analog inputs for external waveforms and auxiliary signals. There's also a Miscellaneous I/O Connector for things like triggers and a voltage output to drive a rotating electrode and a CGME. Be careful, these Inputs and Outputs are not included on many popular potentiostats.
|
||
|
5. I must have a front panel on my
potentiostat.
|
||
|